6
Macro Sensors Tel. (856) 662-8000
11 May, 2006 DMC-A2 Series (ALD-00029)
www.macrosensors.com
Analog Output Scaling Mode (cont.)
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
YES
[_ _ _SELECT
CALIBRATION
CHANNEL]
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
4 Secs
[_ _ _INPUT
SETUP]
START
YES
Input Setup
Calibration
Analog Output
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
Prog.
SP1 SP2 SP4SP3 SP5 SP6
YES
[_ _ _SELECT
ANALOG
OUTPUT]
Prog.
SP1 SP2 SP4SP3 SP5 SP6
[_ _ _SET ZERO VALUE]
Max counts 999999
Min counts –199999
Prog.
SP1 SP2 SP4SP3 SP5 SP6
OR
P
P
P
[_ _ _SET FULL
SCALE VALUE]
Max counts 999999
Min counts –199999
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
[_ _ _SET DATA SOURCE]
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
YES
P
[_ _ _SELECT
SETPOINT]
Setpoints
Set the counts required to be displayed for the
calibrated low analog output value using
the buttons. Press the P button to accept the
new low value.
Set the counts required to be displayed for the
calibrated high analog output value
using the buttons. Press the P button to accept
the new high value.
Select either channel 1 (CH1), channel 2 (CH2),
channel 1 plus 2 (CH 1+2) or channel 1 minus 2 (CH 1-2)
as the source of data for the selected analog output.
P
[_ _ _CALIBRATE OUTPUT]
P
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
OR
Analog Output 1
Analog Output 2
Or press the P button to EXIT
and return to the Operational Display
Analog Output Modules:
AIC: Single 0/4-20 mA
AIV: Single 0-10 V DC
ADV: Dual 0-10 V DC
See Page 3 for further details
Press the button to enter the Input Setup mode
See Page 4 for further details
Press the button to enter the Calibration mode
See Page 4 for further details
Press the button to change the Display
See Page 6 for further details
Press the button to enter the Analog Output mode
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
Select Display
[_ _ _SELECT
DISPLAY]
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Vista de pagina 5
1 2 3 4 5 6 7 8 9 10 11 ... 27 28

Comentarios a estos manuales

Sin comentarios