Macro Sensors Tel. (856) 662-8000
11 May, 2006 DMC-A2 Series (ALD-00029)
www.macrosensors.com
P
P
[_ _ _SELECT CALIBRATION CHANNEL]
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
4 Secs
[_ _ _INPUT
SETUP]
START
YES
Input Setup
Calibration
[_ _ _SET SENSOR TO ZERO POSITION
– – – PRESS P BUTTON TO ACCEPT]
P
[_ _ _ADJUST LVDT SO DISPLAY READS ZERO]
Adjust the sensor to the known zero position. Adjust
the display value using the buttons. Press the
P button to accept the sensor's new zero position.
Adjust the LVDT core until the LVDT output is zero.
P
[_ _ _SET SENSOR TO SPAN POSITION
– – – ENTER SPAN POSITION COUNTS
– – – PRESS P BUTTON TO ACCEPT]
Adjust the sensor to the known span position. Adjust
the display value using the buttons. Press the
P button to accept the sensor's new span position.
ZERO POSITION
Sensor
SPAN POSITION
Sensor
Max counts 999999
Min counts –199999
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Max counts 999999
Min counts –199999
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
Prog.
SP1 SP2 SP4SP3 SP5 SP6
[_ _ _ENTER ZERO OR OFFSET POSITION
– – – PRESS P BUTTON TO ACCEPT]
Adjust the sensor to the known zero or offset position.
Adjust the display value using the buttons. Press
the P button to accept the sensor's new zero or
offset position.
P
OR
OR
Max counts 999999
Min counts –199999
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
OR
P
Prog.
SP1 SP2 SP4SP3 SP5 SP6
[_ _ _SET SENSOR TO KNOWN POSITION
– – – ENTER SPAN POSITION COUNTS
– – – PRESS P BUTTON TO ACCEPT]
Set sensor to known span position. Enter span position
counts using the buttons. Press the P button to accept
the sensor's new span position.
Max counts 999999
Min counts –199999
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
Analog Output
P
YES
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
[_ _ _SELECT
ANALOG
OUTPUT]
Select Display
[_ _ _SELECT
DISPLAY]
This calibration technique allows you
to independently trim the zero setting,
or enter an offset value without altering
the calibrated span range.
Choose (CH1) to display the LVDT 1 position, (CH2)
to display the LVDT 2 position, (CH 1+2) to display the sum
of LVDTs 1 and 2, or (CH 1-2) to display the difference
of LVDTs 1 and 2.
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
YES
P
[_ _ _SELECT
CALIBRATION
METHOD]
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
P
P
OR
This is a dual zero and span
calibration procedure.
Must bring sensor to NULL
position before calibrating.
This calibration technique allows you
to independently trim the span setting
without altering zero position.
Note, when trimming the span value,
the zero offset value is automatically
recalculated and adjusted for the new
scale factor.
See Page 3 for further details
Press the button to enter the Input Setup mode
See Page 5 for further details
Press the button to enter the Analog Output mode
Or press the P button 2 times to
EXIT (bypassing the remaining modes)
and return to the Operational Display
OR
OR
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
Prog.
SP1 SP2 SP4SP3 SP5 SP6
OR
Calibration Mode (Calibration of Sensor Position to Display)
The calibration mode is used to calibrate the physical position
of the sensor to the meter display. The calibration mode
provides four individual calibration techniques. These are:
Adjusting the LVDT until the display reads zero.
A dual position, zero and span calibration procedure.
Independent trimming of the zero position or entry of an
offset value without altering the span.
Independent trimming of the span position or entry of an
offset value without altering the zero.
Note:
Calibration procedures can not be carried out on a
signal (Result, CH1 or CH2) if the signal has an active
linearization table. The table or tables must be disabled
before calibration and then re-activated when calibration is
complete