Macro Sensors Tel. (856) 662-8000
11 May, 2006 DMC-A2 Series (ALD-00029)
www.macrosensors.com
Meter Functions using Serial
Communications
Meter Programming via Serial Port
Serial Communications (cont.)
With a serial output module installed, the meter can be fully
configured using a PC and either:
The Meter Configuration Utility Program.
Or a terminal emulation program such as HyperTerminal.
P
rog
.
SP1 SP2 SP4SP3 SP5 SP6
Figure 12 – Programming via Serial Port
Meter Configuration Utility Program
The meter configuration utility program is an intuitive, user
oriented Windows based interface between the PC and the
meter. In addition to all application function settings, the
configuration program also provides access to the following
additional features.
Configuration Data Copying
This function allows the current meter configuration settings to
be copied and saved for later referral or for restoration.
Macros
A growing library of macros is available to suit a wide range of
standard customer applications. Macros can be installed in the
meter, via the configuration utility program and run
automatically when the meter is powered up.
Terminal Emulation Program
A terminal emulation program, such as HyperTerminal,
provides another interface between a PC and the meter. The
terminal program allows you to read from or write to any
register in the meter using an ASCII character command string.
STEP A Set the HyperTerminal Program Properties
1) Start the Microsoft HyperTerminal program on
the PC.
2) On the File menu, click Properties.
The New Connection Properties dialog box
opens.
Terminal Program Configuration & Use
Procedures
The following procedures describe how to set the Microsoft
HyperTerminal properties, as well as using HyperTerminal to
write to and read from the meter:
3) In the Connect To dialog click the arrow on the
Connect using window and click a COM port
(usually COM2).
4) Click the Configure button.
The COM2 Properties dialog opens.